COURSE 02 / SENSORS & MEASUREMENTS

Start with the physics

Fifteen Sensor Workbench lessons: what you measure, what feels it, what electrical language it speaks, and how to prove the chain.

LOCAL TIME 06:07:24Z

LESSON 01 / 15 · LADDER: WHAT AM I MEASURING? · GUIDED MISSION

The sensor is the beginning

IN PROGRESS
  1. 1 · What am I measuring?
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8

01 · DISCOVER

Your mission

Start with the problem this lesson solves. Everything else builds on it.

MISSION HOOK

Engineering sends a list: wing strain, skin temperature, gearbox vibration, hydraulic pressure, actuator position, shaft RPM, and gear state. Before anyone opens a hardware catalog, a technician asks one question: what physically changes?

EVIDENCE
B · Instrumentation FundamentalC · Teaching SimplificationD · Simulation

TO CONTINUE: READ THE MISSION AND PRESS BEGIN

TECHNICAL DETAILS

Sensor selection begins with a measurement requirement: measurand, range, dynamics, accuracy, environment, and installation. The transducer's output type (resistance, bridge mV/V, thermoelectric emf, charge, IEPE voltage, AC-ratio, pulse train, discrete state, or current) determines conditioning and the acquisition interface family.

  • ›Output type examples: bridge ratio (strain), thermoelectric emf (thermocouple), resistance (RTD/thermistor), charge or IEPE voltage (accelerometer), AC ratio (LVDT/RVDT), pulse frequency (RPM), contact state (discretes).
  • ›Two sensors that measure the same measurand can speak different electrical languages — that alone changes the acquisition choice.
  • ›Acquisition hardware is chosen to fit the documented sensor output, not the other way around.
  • ›Program measurement lists and sensor data sheets control the real decision.

Your place in this mission is remembered on this device for your account (or as a guest) so you can resume. It never counts as lesson completion — only the real checkpoints do. Stage and lesson locks guide learning; they are not a security boundary.

REFERENCES & SOURCES · TAP TO OPEN
B · Instrumentation FundamentalC · Teaching SimplificationD · Simulation
  • B · Instrumentation FundamentalGeneral instrumentation and sensor principles (textbook-level concepts; not tied to any manufacturer document)

    Supports: Measurand-first sensor selection and sensor output types.

  • D · Simulation[SIM]Flight Test Academy Sensor Workbench simulation (original teaching model)

    Supports: Mission board pairings are simplified teaching examples.

CURTISS-WRIGHT FUNCTIONAL-FAMILY BRIDGES (CANDIDATES ONLY)
  • [CTRL]Quarter-bridge resistance change→ KAM quarter-bridge family candidates
  • [CTRL]Full-bridge mV/V→ KAM full-bridge family candidates
  • [CTRL]ICP / IEPE voltage on bias→ Acceleration / ICP-capable family candidate
  • [CW-PUB]Charge→ KAM/CDC/101 functional-family example
  • [CW-PUB]Thermocouple mV→ KAD/TDC family
  • [CW-PUB]Thermistor resistance→ KAD/TDC/101 family-level example (curve compatibility [CTRL])
  • [CTRL]RTD resistance→ Not established — [CTRL]; do not assume any card
  • [CW-PUB]Raw LVDT / RVDT→ KAD/LDC/101 functional-family example
  • [CTRL]Conditioned position voltage→ Suitable voltage ADC family
  • [CTRL]4–20 mA loop→ KAD/CDC/002 candidate family (loop architecture [CTRL])
  • [CW-PUB]Pulse / frequency / period / count→ KAD/DSI family
  • [CW-PUB]DTC pressure scanner→ KAD/MDC/105 special scanner path

Never infer compatibility from overlapping voltage/current numbers or from a measurand name.

  • [MFR-SPEC]Official manufacturer product / datasheet fact
  • [MFR-APP]Official manufacturer application / installation guidance
  • [CW-PUB]Curtiss-Wright public documentation
  • [REF]Authoritative measurement reference (e.g. NIST)
  • [CTRL]Exact compatibility / setup not established — controlled, current documentation required
  • [SIM]Academy teaching simulation — not manufacturer behavior

A = manufacturer verified · B = instrumentation fundamental · C = teaching simplification · D = simulation. B/C/D content is not manufacturer fact.

This learning app does not replace controlled manufacturer or program documentation. Exact revisions, limits, pinouts, compatibility, wiring, and approved test configuration must be verified before live use.